Codecore Logo
Quick Search
»
Advanced Search »

Sanyo PLV-Z Series Projector Driver

RSS
Image
This driver supports the PLV-Z2000, PLV-Z3000 and PLV-Z700.

Manufacturer: Sanyo

Primary Communications Port: Serial


Configuration Settings

  • Serial Port : Serial port that the driver is connected to. Ex. COM1
  • Serial Port Speed : (optional) Baud rate for serial port, 9600 or 19200 (default value is 19200).
  • Input Polling Interval : (optional) Interval time in msec for polling. Default value is 1000.

Events

Power Phase Changed

Occurs when the projector's current power phase changes.

Whenever Filter:

none

EventArgs:

  • Number NewValue : The new property value.
  • Number PreviousValue : The previous property value.

Power State Changed

Occurs when the projector's current power state (on/off) changes.

Whenever Filter:

none

EventArgs:

  • Number NewValue : The new property value.
  • Number PreviousValue : The previous property value.

Source Changed

Occurs when the projector's current source selection changes.

Whenever Filter:

none

EventArgs:

  • Number NewValue : The new property value.
  • Number PreviousValue : The previous property value.

Ready State Changed

The device's running and ready state changed.

Whenever Filter:

none

EventArgs:

  • Number NewValue : The new property value.
  • Number PreviousValue : The previous property value.

Instance Properties

Temperatures

Gets the temperatures for all sensors in the projector.

Accessibility : Read Only

Type: Array

LampTime

Get the total lamp running time in hours.

Accessibility : Read Only

Type: Number

PowerPhase

Gets the current power phase. 0=Standby, 1=Power ON, 2=Processing Countdown, 3=Processing Cooling down, 4=Power Failure, 5=Processing cooling dow due to abnormal temperature, 6=Standby after cooling down due to abnormal temperature or due to door failing, 7=Processing Power Save / Cooling down, 8=Processing Cooling down after OFF due to lam failure, 9=Standby after Cooling down due to lamp failure

Accessibility : Read Only

Type: Number

Power

Gets or sets the power state (on/off) of the projector.

Accessibility : Read / Write

Type: Boolean

Source

Gets or sets the source selection. 0=Video, 1=S-Video, 2=Component1 , 3=Component2, 4=HDMI1, 5=HDMI2, 6=Computer(Analog), 7=Computer(SCART)

Accessibility : Read / Write

Type: Number

DeviceDisplayName

The display name for this device.

Accessibility : Read Only

Type: String

DeviceStartTime

The date and time when this device was started.

Accessibility : Read Only

Type: DateTime

DeviceLifecycleStage

The current lifecycle stage of the device. The stages in order are: Pending Start, Starting, Running, Stopping

Accessibility : Read Only

Type: Number

DeviceIsRunningAndReady

Indicates if the device is ready for use, ie it is in the Running lifecycle stage and all properties are valid and all methods are ready to be used.

Accessibility : Read Only

Type: Boolean

Instance Methods

SendRawCommand ( String )

Sends a command that may otherwise not be supported by the driver. eg. C00

Syntax

void SendRawCommand( String command )

Parameters

command : The command data to send (do not include the 0D terminator.)

SetImageMode ( Number )

Sets the image mode. Please note that some selection are not available on all models.

Syntax

void SetImageMode( Number imageMode )

Parameters

imageMode : Image

0 = Living
1 = Creative Cinema
2 = Pure Cinema
3 = Vivid
4 = Brilliant Cinema
5 = Dynamic
6 = Natural
7 = x.v.Color
8 = User 1
9 = User 2
10 = User 3
11 = User 4
12 = User 5
13 = User 6
14 = User 7

SetScreenSizeMode ( Number )

Sets the screen size mode. Please note that some selection are not available on all models.

Syntax

void SetScreenSizeMode( Number screenSizeMode )

Parameters

screenSizeMode : Screen

0 = Normal
1 = Full
2 = Zoom
3 = Natural Wide 1
4 = Natural Wide 2
5 = Caption In
6 = Full Through
7 = Normal Through
8 = Anamorphic

SetPropertyForDuration ( String, TimeSpan, Object, Object )

Sets a property for a duration of time and then sets the property to a subequent value asynchronously. This action returns after setting the first value and the timer and subsequent property set run in the background. Subsequent sets of the same property will reset the timer if the subsequent value has not yet been set. This is an advanced feature, be sure to set the property name correctly.

Syntax

void SetPropertyForDuration( String propertyName, unknown duration, Object initialValue, Object finalValue )

Parameters

propertyName : The name of the property to set.
duration : The amount of time to wait after setting the initial value to set the subsequent value.
initialValue : The value to set the property to initially.
finalValue : The value to set the property to after the duration of time has passed.

SetPropertyForDuration ( String, Number, TimeSpan, Object, Object )

Sets a property for a duration of time and then sets the property to a subequent value asynchronously. This action returns after setting the first value and the timer and subsequent property set run in the background. Subsequent sets of the same property will reset the timer if the subsequent value has not yet been set. This is an advanced feature, be sure to set the property name correctly.

Syntax

void SetPropertyForDuration( String propertyName, Number arrayIndex, unknown duration, Object initialValue, Object finalValue )

Parameters

propertyName : The name of the property to set.
arrayIndex : The property's array index to set.
duration : The amount of time to wait after setting the initial value to set the subsequent value.
initialValue : The value to set the property to initially.
finalValue : The value to set the property to after the duration of time has passed.

Privacy Policy | Conditions Of Use